Motor Starter Control Transformers (TL490 Series)

Motor Starter Control Transformer (TL490 Series)

Features:

  • Power – 0.04kVA ~ 2.5kVA
  • Frequency – 50/60 Hz
  • High short-time rating power
  • Ambient temperature (ta) – 40°C ~ 50°C
  • Insulation class – class F (155°C)
  • Dielectric strength – 4000Vrms
  • Protection against electric shock: Class I
  • Degree of protection – IP00
  • Unsusceptible to voltage surges or transients
  • Satisfying to EN61558-2-2 “Special requirements for control transformer”

Safety Approval:

 

Terminal:

  • 24A:

screw type connection:

solid- 0.5 – 6 mm2

stranded- 0.5 – 4 mm2

Flat-type connection: 6.3×0.8

 

  • 44A:

screw type connection:

solid- 0.5 – 16 mm2

stranded- 0.5 – 10 mm2

 

All terminal block are labeling with numerical label

 

Product Series Rated Power Dimension (mm) Max. no. of terminals per side Weight
kVA A B C D E F G 24A 44A (kg)
TL490-400 0.04 70.0 76.0 56.0 42.0 50.0 4.8 8.0 6 4 1.1
TL490-630 0.063 77.0 84.0 78.0 64.0 64.0 4.8 8.5 7 4 1.6
TL490-101 0.1 77.0 84.0 78.0 64.0 64.0 4.8 8.5 7 4 2.1
TL490-161 0.16 87.0 96.0 101.0 86.0 84.0 5.8 10.0 8 4 2.85
TL490-251 0.25 87.0 96.0 101.0 86.0 84.0 5.8 10.0 8 4 3.7
TL490-311 0.31 96.0 105.0 103.0 85.6 80.2 5.8 12.0 8 4 4.3
TL490-401 0.4 105.0 117.0 102.0 85.0 90.0 5.8 12.0 10 6 5.1
TL490-501 0.5 105.0 117.0 121.0 104.0 90.0 5.8 12.0 10 6 6.6
TL490-631 0.63 137.0 152.0 110.0 90.0 122.0 7.0 15.0 14 8 8.0
TL490-801 0.8 137.0 152.0 126.0 106.0 122.0 7.0 15.0 14 8 10.2
TL490-102 1.0 137.0 152.0 154.0 134.0 122.0 7.0 15.0 14 8 13.4
TL490-162 1.6 149.0 171.0 150.0 126.0 145.0 7.0 15.0 16 10 19
TL490-202 2.0 149.0 171.0 170.0 146.0 145.0 7.0 15.0 16 10 23
TL490-252 2.5 165.0 190.0 188.0 164.0 160.0 9.0 16.0 16 10 27
Tolerance   typ typ. typ. typ typ ±0.5 ±1.0 approx.

Part Number Designation:

TL490 – XXX R YY – ZZS

Where          XXX    =        Output Power  (0.04kVA ~ 2.5kVA)

                     R        =        Input Style  (“S” = Single; “D” = Double; “M” = multiple; “C” = Center Tapped)

                     YY     =        Input Voltage Range

                     ZZ     =        Output Voltage Range

                        S       =         Suffix for any alphanumeric or letter or blank for marketing purpose

Part No. Rated Power Short-Time Pating Power (PF=0.5) Rated Input Voltage                      Output Voltage (ZZ)                      V
(XXX) kVA kVA (RYY) V (02) (03) (06) (07) (11) (13) (14) (17)
          24 42 110 115 230 2 x 110 2 x 115 2 x 230
TL490-XXXRYY-ZZ (400) 0.04 —- (S01)

(S02)

(S03)

(S04)

(S05)

(S06)

(S07)

(S08)

(S09)

(S10)

(S11)

(S12)

(S13)

(S14)

(S15)

(S16)

(S17)

(S18)

(S19)

100V

110V

115V

117V

120V

200V

220V

230V

240V

277V

300V

380V

400V

415V

440V

480V

500V

550V

600V

· · · · · · · ·
(630) 0.063 0.19 · · · · · · · ·
(101) 0.1 0.31 · · · · · · · ·
(161) 0.16 0.49 · · · · · · · ·
(251) 0.25 0.85 · · · · · · · ·
(311) 0.31 1.12 · · · · · · · ·
(401) 0.4 1.44 · · · · · · · ·
(501) 0.5 2 · · · · · · · ·
(631) 0.63 2.35 · · · · · · · ·
(801) 0.8 3.4 · · · · · · · ·
(102) 1 5 · · · · · · · ·
(162) 1.6 7.3     · · · · · ·
(202) 2 9.7     · · · · · ·
(252) 2.5 13.3     · · · · · ·

Note:  (1) The rated power is only applicable to transformers with separate windings. (not to

                autotransformer).

           (2) Short-time rating power is the most important selection criterion for control transformers.

                 This is required for switching on electromagnetic loads, the output voltage with this load

                 should not drop more than 5% in relation to the rated voltage in order to ensure safe switching.

           (3) Other input voltage (600V max.) can be provided upon request.

           (4) Other output voltage (600V max.) can be provided upon request.

           (5) Other rated power (will not more than 20%) can be provided upon request.

Part No. Rated Power Short-Time Pating Power (PF=0.5) Rated Input Voltage                       Output Voltage (ZZ)                      V
(XXX) kVA kVA (RYY) V (02) (03) (06) (07) (11) (13) (14) (17)
          24 42 110 115 230 2 x 110 2x 115 2 x 230
TL490-XXXRYY-ZZ (400) 0.04 —- (D01)

(D02)

(D03)

(D04)

(D05)

(D06)

(D07)

(D08)

220-380V

230-400V

240-415V

254-440V

265-460V

277-480V

400-460V

550-575V

· · · · · · · ·
(630) 0.063 0.19 · · · · · · · ·
(101) 0.1 0.31 · · · · · · · ·
(161) 0.16 0.49 · · · · · · · ·
(251) 0.25 0.85 · · · · · · · ·
(311) 0.31 1.12 · · · · · · · ·
(401) 0.4 1.44 · · · · · · · ·
(501) 0.5 2 · · · · · · · ·
(631) 0.63 2.35 · · · · · · · ·
(801) 0.8 3.4 · · · · · · · ·
(102) 1 5 · · · · · · · ·
(162) 1.6 7.3     · · · · · ·
(202) 2 9.7     · · · · · ·
(252) 2.5 13.3     · · · · · ·

Note:  (1) The rated power is only applicable to transformers with separate windings. (not to

                autotransformer).

           (2) Short-time rating power is the most important selection criterion for control transformers.

                 This is required for switching on electromagnetic loads, the output voltage with this load

                 should not drop more than 5% in relation to the rated voltage in order to ensure safe switching.

           (3) Other input voltage (600V max.) can be provided upon request.

           (4) Other output voltage (600V max.) can be provided upon request.

           (5) Other rated power (will not more than 20%) can be provided upon request.

Part No. Rated Power Short-Time Pating Power (PF=0.5) Rated Input Voltage                     Output Voltage (ZZ)                        V
(XXX) kVA kVA (RYY) V (02) (03) (06) (07) (11) (13) (14) (17)
          24 42 110 115 230 2 x 110 2x 115 2 x 230
TL490-XXXRYY-ZZ (400) 0.04 —- (M01)

 

 

 

 

(M02)

550- 525- 500- 480- 460- 440- 415- 400- 380- 230- 208V

 

600-575- 550-525- 500-480- 460-440- 415-400- 240-230V

· · · · · · · ·
(630) 0.063 0.19 · · · · · · · ·
(101) 0.1 0.31 · · · · · · · ·
(161) 0.16 0.49 · · · · · · · ·
(251) 0.25 0.85 · · · · · · · ·
(311) 0.31 1.12 · · · · · · · ·
(401) 0.4 1.44 · · · · · · · ·
(501) 0.5 2 · · · · · · · ·
(631) 0.63 2.35 · · · · · · · ·
(801) 0.8 3.4 · · · · · · · ·
(102) 1 5 · · · · · · · ·
(162) 1.6 7.3     · · · · · ·
(202) 2 9.7     · · · · · ·
(252) 2.5 13.3     · · · · · ·

Note:  (1) The rated power is only applicable to transformers with separate windings. (not to

                autotransformer).

           (2) Short-time rating power is the most important selection criterion for control transformers.

                 This is required for switching on electromagnetic loads, the output voltage with this load

                 should not drop more than 5% in relation to the rated voltage in order to ensure safe switching.

           (3) Other input voltage (600V max.) can be provided upon request.

           (4) Other output voltage (600V max.) can be provided upon request.

           (5) Other rated power (will not more than 20%) can be provided upon request.

Part No. Rated Power  Short-Time Pating Power (PF=0.5)  Rated Input Voltage                      Output Voltage (ZZ)                        V
(XXX) kVA kVA (RYY) V (02) (03) (06) (07) (11) (13) (14) (17)
          24 42 110 115 230 2 x 110 2x 115 2 x 230
TL490-XXXRYY-ZZ (400) 0.04 —-  

(C01)

 

 

 

 

(C02)

 

 

 

(C03)

 

 

 

(C04)

 

550- 525- 500- 480- 460- 440- 415- 400- 380- 230- 208V

 

600-575- 550-525- 500-480- 460-440- 415-400- 240-230V

 

480-460- 440-415- 400-380- 230-208V

 

525-500- 480-460- 440-415- 400-240- 230V

· · · · · · · ·
(630) 0.063 0.19 · · · · · · · ·
(101) 0.1 0.31 · · · · · · · ·
(161) 0.16 0.49 · · · · · · · ·
(251) 0.25 0.85 · · · · · · · ·
(311) 0.31 1.12 · · · · · · · ·
(401) 0.4 1.44 · · · · · · · ·
(501) 0.5 2 · · · · · · · ·
(631) 0.63 2.35 · · · · · · · ·
(801) 0.8 3.4 · · · · · · · ·
(102) 1 5 · · · · · · · ·
(162) 1.6 7.3     · · · · · ·
(202) 2 9.7     · · · · · ·
(252) 2.5 13.3     · · · · · ·

Note:  (1) The rated power is only applicable to transformers with separate windings. (not to

                autotransformer).

           (2) Short-time rating power is the most important selection criterion for control transformers.

                 This is required for switching on electromagnetic loads, the output voltage with this load

                 should not drop more than 5% in relation to the rated voltage in order to ensure safe switching.

           (3) Other input voltage (600V max.) can be provided upon request.

           (4) Other output voltage (600V max.) can be provided upon request.

           (5) Other rated power (will not more than 20%) can be provided upon request.

Available Schematics for single style input (S01~S19):

  Terminal Shorted   Terminal Shorted
Rated input Voltage 1-3 Rated input Voltage 1-3
Rated input Voltage –5% 1-2 Rated input Voltage –5% 1-2
Rated input Voltage +5% 1-4 Rated input Voltage +5% 1-4
Rated output Voltage 31-32 Rated output Voltage (Series) 31-34 32-33
      Rated output Voltage (Parallel) 31-34 31-32, 33-34

Note:  (1) Input taps can be optional (for single / double style input only).

           (2) No input tap for input (S19).

           (3) For no input tap (without ±5%), the part number will add a suffix “N”

Available Schematics for double style input (D01~D08):

  Terminal Shorted   Terminal Shorted
Rated input Voltage LV 2-4 Rated input Voltage LV 2-4
Rated input Voltage LV – ‘v’ 3-4 Rated input Voltage LV – ‘v’ 3-4
Rated input Voltage LV + ‘v’ 1-4 Rated input Voltage LV + ‘v’ 1-4
Rated input Voltage HV 2-5 Rated input Voltage HV 2-5
Rated input Voltage HV – ‘v’ 3-5 Rated input Voltage HV – ‘v’ 3-5
Rated input Voltage HV + ‘v’ 1-5 Rated input Voltage HV + ‘v’ 1-5
Rated output Voltage 31-32 Rated output Voltage (Series) 31-34 32-33
      Rated output Voltage (Parallel) 31-34 31-32, 33-34

Note:  (1) Input taps can be optional (for single / double style input only).

           (2) ‘v’ can be “15V” / “20V” / “25V”.

           (3) For no input tap (without ‘v’), the part number will add a suffix “N”.  

           (4) For different ‘v’, the part number will add a unique suffix to represent:

                          “DA“ represent ‘v’ is 15V

                          “DB“ represent ‘v’ is 20V

                          “DC“ represent ‘v’ is 25V

Available Schematics for multiple style input (M01):

  Terminal Shorted   Terminal Shorted
   Rated input Voltage:  550V 1-8 4-5    Rated input Voltage:  550V 1-8 4-5
   Rated input Voltage:  525V 1-8 3-5    Rated input Voltage:  525V 1-8 3-5
   Rated input Voltage:  500V 1-8 2-5    Rated input Voltage:  500V 1-8 2-5
   Rated input Voltage:  480V 1-8 2-5    Rated input Voltage:  480V 1-8 2-5
   Rated input Voltage:  460V 1-8 4-6    Rated input Voltage:  460V 1-8 4-6
   Rated input Voltage:  440V 1-8 3-6    Rated input Voltage:  440V 1-8 3-6
   Rated input Voltage:  415V 1-8 3-7    Rated input Voltage:  415V 1-8 3-7
   Rated input Voltage:  400V 1-8 2-6    Rated input Voltage:  400V 1-8 2-6
   Rated input Voltage:  380V 1-8 2-7    Rated input Voltage:  380V 1-8 2-7
   Rated input Voltage:  230V 1-8 1-6, 4-8    Rated input Voltage:  230V 1-8 1-6, 4-8
   Rated input Voltage:  208V 1-8 1-7, 3-8    Rated input Voltage:  208V 1-8 1-7, 3-8
   Rated output Voltage 31-32    Rated output Voltage (Series) 31-34 32-33
         Rated output Voltage (Parallel) 31-34 31-32, 33-34

Available Schematics for multiple style input (M02):

  Terminal Shorted   Terminal Shorted
   Rated input Voltage:  600V 1-8 4-5    Rated input Voltage:  600V 1-8 4-5
   Rated input Voltage:  575V 1-8 4-6    Rated input Voltage:  575V 1-8 4-6
   Rated input Voltage:  550V 1-8 4-7    Rated input Voltage:  550V 1-8 4-7
   Rated input Voltage:  525V 1-8 3-5    Rated input Voltage:  525V 1-8 3-5
   Rated input Voltage:  500V 1-8 3-6    Rated input Voltage:  500V 1-8 3-6
   Rated input Voltage:  480V 1-8 3-7    Rated input Voltage:  480V 1-8 3-7
   Rated input Voltage:  460V 1-8 3-7    Rated input Voltage:  460V 1-8 3-7
   Rated input Voltage:  440V 1-8 2-5    Rated input Voltage:  440V 1-8 2-5
   Rated input Voltage:  415V 1-8 2-6    Rated input Voltage:  415V 1-8 2-6
   Rated input Voltage:  400V 1-8 2-7    Rated input Voltage:  400V 1-8 2-7
   Rated input Voltage:  240V 1-8 1-7, 3-8    Rated input Voltage:  240V 1-8 1-7, 3-8
   Rated input Voltage:  230V 1-8 1-7, 3-8    Rated input Voltage:  230V 1-8 1-7, 3-8
   Rated output Voltage 31-32    Rated output Voltage (Series) 31-34 32-33
         Rated output Voltage (Parallel) 31-34 31-32, 33-34

Available Schematics for center tapped style input (C01):

  Terminal Shorted   Terminal Shorted
   Rated input Voltage:  550V 1-7    Rated input Voltage:  550V 1-7
   Rated input Voltage:  525V 2-7    Rated input Voltage:  525V 2-7 — 
   Rated input Voltage:  500V 3-7    Rated input Voltage:  500V 3-7 — 
   Rated input Voltage:  480V 1-6    Rated input Voltage:  480V 1-6 — 
   Rated input Voltage:  460V 2-6    Rated input Voltage:  460V 2-6 — 
   Rated input Voltage:  440V 3-6    Rated input Voltage:  440V 3-6 — 
   Rated input Voltage:  415V 1-5    Rated input Voltage:  415V 1-5 — 
   Rated input Voltage:  400V 2-5    Rated input Voltage:  400V 2-5 — 
   Rated input Voltage:  380V 3-5    Rated input Voltage:  380V 3-5 — 
   Rated input Voltage:  230V 2-4    Rated input Voltage:  230V 2-4 — 
   Rated input Voltage:  208V 3-4    Rated input Voltage:  208V 3-4 — 
   Rated output Voltage 31-32    Rated output Voltage (Series) 31-34 32-33
         Rated output Voltage (Parallel) 31-34 31-32, 33-34

Available Schematics for center tapped style input (C02):

  Terminal Shorted   Terminal Shorted
   Rated input Voltage:  600V 1-7    Rated input Voltage:  600V 1-7
   Rated input Voltage:  575V 2-7    Rated input Voltage:  575V 2-7
   Rated input Voltage:  550V 3-7    Rated input Voltage:  550V 3-7
   Rated input Voltage:  525V 1-6    Rated input Voltage:  525V 1-6
   Rated input Voltage:  500V 2-6    Rated input Voltage:  500V 2-6
   Rated input Voltage:  480V 3-6    Rated input Voltage:  480V 3-6
   Rated input Voltage:  460V 1-5    Rated input Voltage:  460V 1-5
   Rated input Voltage:  440V 2-5    Rated input Voltage:  440V 2-5
   Rated input Voltage:  415V 3-5    Rated input Voltage:  415V 3-5
   Rated input Voltage:  400V 3-5    Rated input Voltage:  400V 3-5
   Rated input Voltage:  240V 1-4    Rated input Voltage:  240V 1-4
   Rated input Voltage:  230V 2-4    Rated input Voltage:  230V 2-4
   Rated output Voltage 31-32    Rated output Voltage (Series) 31-34 32-33
         Rated output Voltage (Parallel) 31-34 31-32, 33-34

Available Schematics for center tapped style input (C03):

  Terminal Shorted   Terminal Shorted
   Rated input Voltage:  480V 1-6    Rated input Voltage:  480V 1-6
   Rated input Voltage:  460V 2-6    Rated input Voltage:  460V 2-6 — 
   Rated input Voltage:  440V 3-6    Rated input Voltage:  440V 3-6 — 
   Rated input Voltage:  415V 1-5    Rated input Voltage:  415V 1-5 — 
   Rated input Voltage:  400V 2-5    Rated input Voltage:  400V 2-5 — 
   Rated input Voltage:  380V 3-5    Rated input Voltage:  380V 3-5 — 
   Rated input Voltage:  230V 2-4    Rated input Voltage:  230V 2-4 — 
   Rated input Voltage:  208V 3-4    Rated input Voltage:  208V 3-4 — 
   Rated output Voltage 31-32    Rated output Voltage (Series) 31-34 32-33
         Rated output Voltage (Parallel) 31-34 31-32, 33-34

Available Schematics for center tapped style input (C04):

  Terminal Shorted   Terminal Shorted
   Rated input Voltage:  525V 1-6    Rated input Voltage:  525V 1-6
   Rated input Voltage:  500V 2-6    Rated input Voltage:  500V 2-6
   Rated input Voltage:  480V 3-6    Rated input Voltage:  480V 3-6
   Rated input Voltage:  460V 1-5    Rated input Voltage:  460V 1-5
   Rated input Voltage:  440V 2-5    Rated input Voltage:  440V 2-5
   Rated input Voltage:  415V 3-5    Rated input Voltage:  415V 3-5
   Rated input Voltage:  400V 3-5    Rated input Voltage:  400V 3-5
   Rated input Voltage:  240V 1-4    Rated input Voltage:  240V 1-4
   Rated input Voltage:  230V 2-4    Rated input Voltage:  230V 2-4
   Rated output Voltage 31-32    Rated output Voltage (Series) 31-34 32-33
         Rated output Voltage (Parallel) 31-34 31-32, 33-34
Product Catalog